Skip to Content

Microclimate Stations and Hazardous Gas Detection Thresholds

Taiwan occupational safety and health regulations and the project contract specifications take precedence
October 4, 2026 by
Microclimate Stations and Hazardous Gas Detection Thresholds
永億資訊有限公司

Detection Threshold Table

Safe Warning Stop Work Immediately

ItemUnit Safe Warning Stop Work Immediately
Hazardous Gases
Oxygen O₂% VOL 19.5 – 23.5 16 – 19.5
23.5 – 25
< 16 or > 25
Carbon Monoxide COppm < 25 25 – 50 > 50
Hydrogen Sulfide H₂Sppm < 1 1 – 10 > 10
Combustible Gas LEL% LEL < 10 10 – 25 > 25
Microclimate Station
Heat Index°C < 33 33 – 41 > 41
Wind Speedm/s < 10.8 10.8 – 17.2 > 17.2
NoisedB(A) < 85 85 – 100 > 115
PM2.5µg/m³ < 35.5 35.5 – 150 > 150
PM10µg/m³ < 54 54 – 254 > 254

Subject to Taiwan's occupational safety and health regulations and the construction contract specifications.

The table above shows the three-level on-site detection classification (safe, warning, stop work immediately). The sections below summarize the corresponding legal basis and reference values; where the two differ, follow the regulations and the construction contract specifications.

This article summarizes the microclimate and hazardous gas monitoring items commonly found on construction sites, with the main legal basis and reference values, for reference when setting detection thresholds. Actual thresholds are subject to the latest regulatory announcements and the construction contract specifications.

Main Regulatory Sources

RegulationCompetent AuthorityApplicable Items
Regulations on Occupational Safety and Health FacilitiesMinistry of LaborO₂, combustible gas, noise, heat hazard
Permissible Exposure Limits of Hazardous Substances in the Workplace
(formerly "Standards for Permissible Concentrations of Hazardous Substances in the Air of Workers' Working Environments")
Ministry of LaborCO, H₂S, noise
Construction Safety and Health Facility StandardsMinistry of LaborWind speed, work at height
Safety Regulations for Cranes and Hoisting EquipmentMinistry of LaborWind speed (hoisting work)
Air Quality Index (AQI)Ministry of EnvironmentPM2.5、PM10
Regulations Governing Air Pollution Control Facilities for Construction ProjectsMinistry of EnvironmentPM2.5、PM10
OSHA 29 CFR 1910.146、1910.1000US OSHA (reference)O₂、CO、H₂S、LEL
NIOSH recommended exposure limitsUS NIOSH (reference)CO、H₂S
Heat hazard prevention for high-temperature outdoor work (heat index table, heat hazard risk levels)Occupational Safety and Health Administration, Ministry of Labor (cited through the Taoyuan City Government Maintenance Engineering Office plan)Heat Index

Quick Reference of Regulatory Values

ItemReference ThresholdBasis
Oxygen (O₂)Below 18% is oxygen deficient; recommended alarm limits are 19.5% lower and 23.5% upperOccupational safety and health facility regulations; OSHA (reference)
Carbon monoxide (CO)8-hour TWA 35 ppmPermissible Exposure Limits of Hazardous Substances in the Workplace
Hydrogen sulfide (H₂S)8-hour TWA 10 ppmPermissible Exposure Limits of Hazardous Substances in the Workplace
Combustible gas (LEL)Stop hot work at 30% LEL or above; alarm set at 10% LEL as standardOccupational safety and health facility regulations; OSHA / NFPA (reference)
Heat Index (°C)Level 1: 26.7 and above, below 32.2; Level 2: 32.2 and above, below 40.6; Level 3: 40.6 and above, below 54.4; Level 4: 54.4 and aboveHeat hazard risk levels (see the dedicated article "Heat Index: Temperature-Humidity Chart and Heat Hazard Risk Levels")
Wind SpeedStop open-air work at height when the 10-minute average wind speed reaches 10 m/s or aboveConstruction Safety and Health Facility Standards
Noise8-hour TWA 90 dB(A); hearing protection at 85 dB(A); no exposure above 115 dB(A) at any timePermissible Exposure Limits of Hazardous Substances in the Workplace; occupational safety and health facility regulations
PM2.524-hour value: unhealthy for sensitive groups from 35.5 µg/m³AQI
PM1024-hour value: unhealthy for sensitive groups from 126 µg/m³AQI

Hazardous Gases

Oxygen (O₂)

Under the Regulations on Occupational Safety and Health Facilities, an oxygen concentration below 18% is an oxygen-deficient environment, and the work environment should be kept at 18% or above. In practice, OSHA 29 CFR 1910.146 is widely referenced, using 19.5% as the safe lower limit and 23.5% as the oxygen-enriched upper limit.

Carbon monoxide (CO)

Under the Permissible Exposure Limits of Hazardous Substances in the Workplace, the 8-hour time-weighted average (TWA) permissible concentration of CO is 35 ppm. Reference values: the OSHA PEL is 50 ppm (TWA); NIOSH recommends a TWA of 35 ppm, and never exceeding 200 ppm at any time (Ceiling).

Hydrogen sulfide (H₂S)

Under the Permissible Exposure Limits of Hazardous Substances in the Workplace, the 8-hour TWA of H₂S is 10 ppm. Reference values: OSHA sets a ceiling of 20 ppm, and with no other exposure a single 10-minute exposure must not exceed 50 ppm (Peak); NIOSH recommends a 10-minute ceiling of 10 ppm, and the Immediately Dangerous to Life or Health (IDLH) concentration is 100 ppm.

Combustible gas (LEL)

Under the Regulations on Occupational Safety and Health Facilities, when the combustible gas concentration at a work site reaches 30% of the lower explosive limit (LEL) or above, hot work and any work that may cause sparks must stop. International practice (OSHA / NFPA) usually uses 10% LEL as the alarm threshold; the alarm can be set in low and high stages, and evacuation conditions are decided according to on-site work rules.

Microclimate

Heat Index

Under Article 324-6 of the Regulations on Occupational Safety and Health Facilities, employers must take heat hazard prevention measures for workers doing outdoor work at high temperatures. The heat index is assessed from temperature and relative humidity and divided into Levels 1 to 4 (26.7, 32.2, 40.6 and 54.4°C are the level boundaries). For the complete chart reading method, temperature-humidity chart, preventive measures at each level and sources, see the dedicated article "Heat Index: Temperature-Humidity Chart and Heat Hazard Risk Levels"。

Wind Speed

Under the Construction Safety and Health Facility Standards, open-air work at height must stop in strong wind (10-minute average wind speed of 10 m/s or above). Hoisting work is also subject to the Safety Regulations for Cranes and Hoisting Equipment and the equipment manufacturer's rules; work must stop when wind speed reaches the limit or during a typhoon warning.

Noise

Under the Permissible Exposure Limits of Hazardous Substances in the Workplace, the permissible 8-hour time-weighted sound pressure level is 90 dB(A), and no exposure above 115 dB(A) is allowed at any time (impact noise is counted separately). For work sites where noise reaches 85 dB(A), hearing protection measures must be implemented and protective equipment provided under the Regulations on Occupational Safety and Health Facilities.

PM2.5 and PM10

Based on the Ministry of Environment Air Quality Index (AQI) categories:

LevelPM2.5(µg/m³)PM10(µg/m³)
Good0 – 15.40 – 54
Moderate15.5 – 35.455 – 125
Unhealthy for sensitive groups35.5 – 54.4126 – 254
Unhealthy for all groups54.5 – 150.4255 – 354

Site dust control is carried out under the Regulations Governing Air Pollution Control Facilities for Construction Projects, which require dust nets, sprinkling and other control facilities.


This article is a general summary and does not constitute a legal interpretation. Regulations and announcements may be revised; before setting thresholds, check the latest announcements of the competent authority, and follow the construction contract specifications. Compiled: October 2026.

Heat Index Level Linkage: Automatic Sprinklers and Voice Announcements
Level 2–4 lights, sprinkler schedules and voice announcement content