Detection Threshold Table
Safe Warning Stop Work Immediately
| Item | Unit | Safe | Warning | Stop Work Immediately |
|---|---|---|---|---|
| Hazardous Gases | ||||
| Oxygen O₂ | % VOL | 19.5 – 23.5 | 16 – 19.5 23.5 – 25 |
< 16 or > 25 |
| Carbon Monoxide CO | ppm | < 25 | 25 – 50 | > 50 |
| Hydrogen Sulfide H₂S | ppm | < 1 | 1 – 10 | > 10 |
| Combustible Gas LEL | % LEL | < 10 | 10 – 25 | > 25 |
| Microclimate Station | ||||
| Heat Index | °C | < 33 | 33 – 41 | > 41 |
| Wind Speed | m/s | < 10.8 | 10.8 – 17.2 | > 17.2 |
| Noise | dB(A) | < 85 | 85 – 100 | > 115 |
| PM2.5 | µg/m³ | < 35.5 | 35.5 – 150 | > 150 |
| PM10 | µg/m³ | < 54 | 54 – 254 | > 254 |
Subject to Taiwan's occupational safety and health regulations and the construction contract specifications.
The table above shows the three-level on-site detection classification (safe, warning, stop work immediately). The sections below summarize the corresponding legal basis and reference values; where the two differ, follow the regulations and the construction contract specifications.
This article summarizes the microclimate and hazardous gas monitoring items commonly found on construction sites, with the main legal basis and reference values, for reference when setting detection thresholds. Actual thresholds are subject to the latest regulatory announcements and the construction contract specifications.
Main Regulatory Sources
| Regulation | Competent Authority | Applicable Items |
|---|---|---|
| Regulations on Occupational Safety and Health Facilities | Ministry of Labor | O₂, combustible gas, noise, heat hazard |
| Permissible Exposure Limits of Hazardous Substances in the Workplace (formerly "Standards for Permissible Concentrations of Hazardous Substances in the Air of Workers' Working Environments") | Ministry of Labor | CO, H₂S, noise |
| Construction Safety and Health Facility Standards | Ministry of Labor | Wind speed, work at height |
| Safety Regulations for Cranes and Hoisting Equipment | Ministry of Labor | Wind speed (hoisting work) |
| Air Quality Index (AQI) | Ministry of Environment | PM2.5、PM10 |
| Regulations Governing Air Pollution Control Facilities for Construction Projects | Ministry of Environment | PM2.5、PM10 |
| OSHA 29 CFR 1910.146、1910.1000 | US OSHA (reference) | O₂、CO、H₂S、LEL |
| NIOSH recommended exposure limits | US NIOSH (reference) | CO、H₂S |
| Heat hazard prevention for high-temperature outdoor work (heat index table, heat hazard risk levels) | Occupational Safety and Health Administration, Ministry of Labor (cited through the Taoyuan City Government Maintenance Engineering Office plan) | Heat Index |
Quick Reference of Regulatory Values
| Item | Reference Threshold | Basis |
|---|---|---|
| Oxygen (O₂) | Below 18% is oxygen deficient; recommended alarm limits are 19.5% lower and 23.5% upper | Occupational safety and health facility regulations; OSHA (reference) |
| Carbon monoxide (CO) | 8-hour TWA 35 ppm | Permissible Exposure Limits of Hazardous Substances in the Workplace |
| Hydrogen sulfide (H₂S) | 8-hour TWA 10 ppm | Permissible Exposure Limits of Hazardous Substances in the Workplace |
| Combustible gas (LEL) | Stop hot work at 30% LEL or above; alarm set at 10% LEL as standard | Occupational safety and health facility regulations; OSHA / NFPA (reference) |
| Heat Index (°C) | Level 1: 26.7 and above, below 32.2; Level 2: 32.2 and above, below 40.6; Level 3: 40.6 and above, below 54.4; Level 4: 54.4 and above | Heat hazard risk levels (see the dedicated article "Heat Index: Temperature-Humidity Chart and Heat Hazard Risk Levels") |
| Wind Speed | Stop open-air work at height when the 10-minute average wind speed reaches 10 m/s or above | Construction Safety and Health Facility Standards |
| Noise | 8-hour TWA 90 dB(A); hearing protection at 85 dB(A); no exposure above 115 dB(A) at any time | Permissible Exposure Limits of Hazardous Substances in the Workplace; occupational safety and health facility regulations |
| PM2.5 | 24-hour value: unhealthy for sensitive groups from 35.5 µg/m³ | AQI |
| PM10 | 24-hour value: unhealthy for sensitive groups from 126 µg/m³ | AQI |
Hazardous Gases
Oxygen (O₂)
Under the Regulations on Occupational Safety and Health Facilities, an oxygen concentration below 18% is an oxygen-deficient environment, and the work environment should be kept at 18% or above. In practice, OSHA 29 CFR 1910.146 is widely referenced, using 19.5% as the safe lower limit and 23.5% as the oxygen-enriched upper limit.
Carbon monoxide (CO)
Under the Permissible Exposure Limits of Hazardous Substances in the Workplace, the 8-hour time-weighted average (TWA) permissible concentration of CO is 35 ppm. Reference values: the OSHA PEL is 50 ppm (TWA); NIOSH recommends a TWA of 35 ppm, and never exceeding 200 ppm at any time (Ceiling).
Hydrogen sulfide (H₂S)
Under the Permissible Exposure Limits of Hazardous Substances in the Workplace, the 8-hour TWA of H₂S is 10 ppm. Reference values: OSHA sets a ceiling of 20 ppm, and with no other exposure a single 10-minute exposure must not exceed 50 ppm (Peak); NIOSH recommends a 10-minute ceiling of 10 ppm, and the Immediately Dangerous to Life or Health (IDLH) concentration is 100 ppm.
Combustible gas (LEL)
Under the Regulations on Occupational Safety and Health Facilities, when the combustible gas concentration at a work site reaches 30% of the lower explosive limit (LEL) or above, hot work and any work that may cause sparks must stop. International practice (OSHA / NFPA) usually uses 10% LEL as the alarm threshold; the alarm can be set in low and high stages, and evacuation conditions are decided according to on-site work rules.
Microclimate
Heat Index
Under Article 324-6 of the Regulations on Occupational Safety and Health Facilities, employers must take heat hazard prevention measures for workers doing outdoor work at high temperatures. The heat index is assessed from temperature and relative humidity and divided into Levels 1 to 4 (26.7, 32.2, 40.6 and 54.4°C are the level boundaries). For the complete chart reading method, temperature-humidity chart, preventive measures at each level and sources, see the dedicated article "Heat Index: Temperature-Humidity Chart and Heat Hazard Risk Levels"。
Wind Speed
Under the Construction Safety and Health Facility Standards, open-air work at height must stop in strong wind (10-minute average wind speed of 10 m/s or above). Hoisting work is also subject to the Safety Regulations for Cranes and Hoisting Equipment and the equipment manufacturer's rules; work must stop when wind speed reaches the limit or during a typhoon warning.
Noise
Under the Permissible Exposure Limits of Hazardous Substances in the Workplace, the permissible 8-hour time-weighted sound pressure level is 90 dB(A), and no exposure above 115 dB(A) is allowed at any time (impact noise is counted separately). For work sites where noise reaches 85 dB(A), hearing protection measures must be implemented and protective equipment provided under the Regulations on Occupational Safety and Health Facilities.
PM2.5 and PM10
Based on the Ministry of Environment Air Quality Index (AQI) categories:
| Level | PM2.5(µg/m³) | PM10(µg/m³) |
|---|---|---|
| Good | 0 – 15.4 | 0 – 54 |
| Moderate | 15.5 – 35.4 | 55 – 125 |
| Unhealthy for sensitive groups | 35.5 – 54.4 | 126 – 254 |
| Unhealthy for all groups | 54.5 – 150.4 | 255 – 354 |
Site dust control is carried out under the Regulations Governing Air Pollution Control Facilities for Construction Projects, which require dust nets, sprinkling and other control facilities.
This article is a general summary and does not constitute a legal interpretation. Regulations and announcements may be revised; before setting thresholds, check the latest announcements of the competent authority, and follow the construction contract specifications. Compiled: October 2026.