Under Article 324-6 of the Regulations on Occupational Safety and Health Facilities, employers must take heat hazard prevention measures for workers doing outdoor work at high temperatures. The heat index is an indicator that assesses human heat stress from temperature and relative humidity. First find the heat index value for the site, then take the corresponding measures according to the risk level.
How to Read the Chart
- Obtain the temperature and relative humidity of the work site: use readings from the work location or a nearby weather station; if measuring devices are installed on site and records are kept, the actual measurements may be used.
- In the "Heat Index Table" below, find the temperature on the vertical axis and the relative humidity on the horizontal axis; the corresponding value is the heat index.
- If the exact temperature or humidity is not listed, take the higher temperature or humidity in the table. For example, for 32.0°C and 67% on site, use 32.2°C and 70% to get 40.6.
- When changes in the environment during work raise the risk level, measures must immediately be taken according to the higher level.
Heat Hazard Risk Levels
| Level | Heat Index (°C) | Risk Management Principles |
|---|---|---|
| Level 1 | 26.7 and above, below 32.2 | Basic protection against heat exposure. Stay alert when doing heavy physical work and take necessary protective measures. |
| Level 2 | 32.2 and above, below 40.6 | Implement hazard prevention measures and raise hazard awareness. |
| Level 3 | 40.6 and above, below 54.4 | Strengthen prevention and management measures, avoid having workers do outdoor work during high-temperature periods, and watch workers' physical condition. |
| Level 4 | 54.4 and above | Implement protective measures more actively and avoid having workers do outdoor work; where it is truly necessary, implement the corresponding measures and strengthen emergency response mechanisms. |
The following stricter rules also apply to the assessment:
- Workers working in direct sunlight, or wearing airtight, heavy or impermeable protective clothing, should have the assessed risk level raised by one level; where it is already the highest level, no one may be assigned to outdoor work except for emergency rescue.
- For heavy physical work, reduce working time, rest at least 20 minutes every hour, and replace manual labor with machinery wherever possible.
- When the Central Weather Administration issues heat information (yellow: temperature of 36°C or above; orange: 36°C or above for 3 or more days, or 38°C or above; red: 38°C or above for 3 or more days), the level has usually reached Level 3 or higher, so be especially alert.
Heat Index Table (Temperature × Relative Humidity)
The vertical axis is temperature (°C) and the horizontal axis is relative humidity (%). Colors correspond to Levels 1 to 4 in the table above; "▲" means a higher heat index, which is Level 4.
| Temp. / Humidity | 40% | 45% | 50% | 55% | 60% | 65% | 70% | 75% | 80% | 85% | 90% | 95% | 100% |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 43.3 | 57.8 | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ |
| 42.2 | 54.4 | 58.3 | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ |
| 41.1 | 51.1 | 54.4 | 58.3 | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ |
| 40.0 | 48.3 | 51.1 | 55.0 | 58.3 | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ |
| 38.9 | 45.6 | 48.3 | 51.1 | 54.4 | 58.3 | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ |
| 37.8 | 42.8 | 45.6 | 47.8 | 51.1 | 53.9 | 57.8 | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ |
| 36.7 | 40.6 | 42.8 | 45.0 | 47.2 | 50.6 | 53.3 | 56.7 | ▲ | ▲ | ▲ | ▲ | ▲ | ▲ |
| 35.6 | 38.3 | 40.0 | 42.2 | 44.4 | 46.7 | 49.4 | 52.2 | 55.6 | 58.9 | ▲ | ▲ | ▲ | ▲ |
| 34.4 | 36.1 | 37.8 | 39.4 | 41.1 | 43.3 | 45.6 | 48.3 | 51.1 | 53.9 | 57.2 | ▲ | ▲ | ▲ |
| 33.3 | 34.4 | 35.6 | 37.2 | 38.3 | 40.6 | 42.2 | 44.4 | 46.7 | 49.4 | 52.2 | 55.0 | 58.3 | ▲ |
| 32.2 | 32.8 | 33.9 | 35.0 | 36.1 | 37.8 | 39.4 | 40.6 | 42.8 | 45.0 | 47.2 | 50.0 | 52.8 | 55.6 |
| 31.1 | 31.1 | 31.7 | 32.8 | 33.9 | 35.0 | 36.7 | 37.8 | 39.4 | 41.1 | 43.3 | 45.0 | 47.2 | 49.4 |
| 30.0 | 29.4 | 30.6 | 31.1 | 31.7 | 32.8 | 33.9 | 35.0 | 36.1 | 37.8 | 38.9 | 40.6 | 42.2 | 44.4 |
| 28.9 | 28.3 | 28.9 | 29.4 | 30.0 | 31.1 | 31.7 | 32.2 | 33.3 | 34.4 | 35.6 | 36.7 | 37.8 | 39.4 |
| 27.8 | 27.2 | 27.8 | 28.3 | 28.9 | 28.9 | 29.4 | 30.0 | 31.1 | 31.7 | 32.2 | 32.8 | 33.9 | 35.0 |
| 26.7 | 26.7 | 26.7 | 27.2 | 27.2 | 27.8 | 27.8 | 28.3 | 28.9 | 28.9 | 29.4 | 30.0 | 30.0 | 30.6 |
Preventive Measures by Level
| Measure | Level 1 | Level 2 | Level 3 | Level 4 |
|---|---|---|---|---|
| Reduce workers' exposure temperature and inspect work on site | ● | ● | ● | ● |
| Provide suitable rest areas and work clothing | ● | ● | ● | ● |
| Provide sufficient drinking water and electrolytes | ● | ● | ● | ● |
| Adjust workers' heat acclimatization and working hours | ● | ● | ● | |
| Use personal protective equipment* | ● | ● | ||
| Appropriately select workers, self-managed personal health, and confirm health status | ● | ● | ● | ● |
| Heat hazard prevention safety and health training | ● | ● | ● | ● |
| Establish emergency response mechanisms and administer first aid | ● | ● | ● | ● |
* Personal protective equipment is the last line of defense for workers. Consider it when administrative and engineering controls cannot effectively reduce heat stress.
Sources: Taoyuan City Government Maintenance Engineering Office, "Heat Hazard Prevention Plan for High-Temperature Outdoor Work" (Appendix 1 "Heat Index Table", Appendix 2 "Heat Index and Risk Management Principles Corresponding to Heat Hazard Risk Levels", Appendix 3 "Hazard Prevention and Management Measures for Different Heat Hazard Risk Levels"), whose legal basis is Article 324-6 of the Regulations on Occupational Safety and Health Facilities, and which directs use of the Occupational Safety and Health Administration of the Ministry of Labor's High-Temperature Outdoor Work Heat Hazard Prevention Action Information Website and the temperature and relative humidity data of the Central Weather Bureau of the Ministry of Transportation and Communications (now the Central Weather Administration). Cited on October 4, 2026.
This article is a general summary and does not constitute a legal interpretation. Regulations and announcements may be revised; before putting it into practice, check the latest announcements of the competent authority, and follow the construction contract specifications. For the detection thresholds, see "Microclimate Stations and Hazardous Gas Detection Thresholds"。