Product Overview
The JNC S400-SO horizontal rotating edition is a multi-channel rotating Chinese LED outdoor display using a color P4 full-color LED panel, arranged horizontally, cycling through each environmental sensor's channel name, value and unit, so residents, workers and managers around the site can clearly read air quality, noise, temperature and humidity and other environmental information from afar. The main difference from the vertical version is the horizontal rotation display method, showing the full information of one channel at a time, suited to site entrances or public roadsides with a wide field of view.
Key Features
Horizontal Rotating EditionHorizontal Rotating vs. Vertical - How to Choose?
- Horizontal installation, wide visual field
- Shows one channel at a time (full information)
- Channels cycle in turn
- Suited to open locations
- Road works, plazas, plant exits
- Vertical installation, saves space
- Two rows shown at the same time
- Two channels visible at once
- Suited to site office doors
- Space-limited entrances
PM2.5: 31.2 μg/m³ (stays N seconds) → Noise: 68.5 dB (stays N seconds) → Temperature: 28.3°C (stays N seconds) → CO2: 412 ppm (stays N seconds) → loops...
The dwell time in seconds can be customized in the Web Service interface; 5–10 seconds per channel is recommended.
Sensor Data That Can Be Displayed
RS-485 / ModbusShows site temperature (°C) and relative humidity (%) in real time, switching to a warning color at high temperatures to flag heat hazard risk.
Shows fine particulate concentration (μg/m³); when AQI standards are exceeded the LED switches to a red warning automatically, supporting site dust control requirements.
Shows CO2 concentration (ppm), suited to indoor air quality monitoring in site offices; exceeding limits automatically triggers ventilation equipment.
Shows construction noise levels in real time, meeting community-relations regulatory requirements; alerts are pushed when exceeded to remind the contractor to take noise reduction measures.
Integrated weather station sensor shows real-time wind speed (m/s) and direction, and displays a "Stop Work Warning" message when limits are exceeded for work at height.
Shows hazardous gas concentration, suited to confined spaces such as chemical plants, warehouses and basements, ensuring workers' environmental safety.
Automatic Alarm Color Switching Mechanism
Values are within the normal range; the LED shows green values, indicating good environmental quality.
Values reach the HI or LO alarm threshold; the LED switches to yellow to remind people to watch environmental changes.
Values reach the severe HH or LL alarm threshold; the LED switches to flashing red and triggers the relay output for linked alarms.
The four-level thresholds (HH/HI/LO/LL) for each channel can be set individually through the Web Service interface, flexibly meeting different sites' management standards.
Web Service Management Functions
Connect with a phone or computer browser to see all channel values, alarm status and rotation settings in real time; Traditional Chinese / English interface supported.
Set the channel rotation order, dwell seconds per channel, text color and scrolling effect, fully customized to site needs.
View daily, weekly and monthly trend charts, query each channel's maximum, minimum and time of occurrence, and download historical CSV records.
1 relay output can control ventilation equipment, voice & strobe alarms or defogging total heat exchangers, achieving automated environmental control.
Installation and Connection
The S400-SO horizontal edition is installed horizontally, with 4 fixing holes on top of the housing; suited to wall mounting on site entrance walls or posts, with a recommended height of 1.5–2.5 m to keep it in line of sight.
① +24V/GND power (DC 9–36V or AC 100–240V) ② D+/D- RS-485 to sensors ③ RJ-45 Ethernet or Wi-Fi setup ④ COM/NO relay output for linked alarms.
Search for the "JNC IAQ SENSOR" Wi-Fi on a phone and connect, enter 192.168.0.140 in a browser to reach the Web Service, and complete the IP settings, sensor channel settings and rotation order settings.
Connect S400 data to the 4S360 environmental monitoring system via Modbus TCP to manage multiple boards and sensors together, with LINE/Teams threshold alert push integrated.
Applications
Need advice on choosing an LED horizontal rotating board?
Based on installation location, sensor needs and system integration plan, we provide the most suitable model configuration and a complete quote.