Light off · Level 1
Heat index 26.7 and above, below 32.2
Light off; automatic sprinkler linkage and voice announcements are not activated; linkage starts from Level 2.
Heat Hazard Response
A microclimate station measures on-site temperature and relative humidity, and automatically lights the indicator, starts sprinklers and plays voice announcements according to the heat index level, so heat protection for outdoor work in high temperatures does not depend on people watching.
Detect, decide, act - three steps chained together automatically.
Heat index 26.7 and above, below 32.2
Light off; automatic sprinkler linkage and voice announcements are not activated; linkage starts from Level 2.
Heat index 32.2 and above, below 40.6
11:00–14:00 spray 5 minutes, pause 10 minutes; voice announcement once an hour.
Heat index 40.6 and above, below 54.4
11:00–14:00 spray 10 minutes, pause 10 minutes; voice announcement once an hour.
Heat index 54.4 and above
11:00–14:00 spray 10 minutes, pause 5 minutes; voice with warning sound every 30 minutes.
When relative humidity is above 70%, automatic sprinklers pause. At other hours they start manually and stop automatically after running 20 minutes. For the complete rules and announcement content, see "Heat Index Level Linkage: Automatic Sprinklers and Voice Announcements"。