Skip to Content

Heat Hazard Response

Heat Hazard Linkage

A microclimate station measures on-site temperature and relative humidity, and automatically lights the indicator, starts sprinklers and plays voice announcements according to the heat index level, so heat protection for outdoor work in high temperatures does not depend on people watching.

Linkage Flow

Detect, decide, act - three steps chained together automatically.

1 Detect Microclimate station Temperature, humidity → heat index 2 Decide PLC controller Switches outputs by level 3 Act Light, sprinklers, voice

Light off · Level 1

Heat index 26.7 and above, below 32.2

Light off; automatic sprinkler linkage and voice announcements are not activated; linkage starts from Level 2.

Green · Level 2

Heat index 32.2 and above, below 40.6

11:00–14:00 spray 5 minutes, pause 10 minutes; voice announcement once an hour.

Yellow · Level 3

Heat index 40.6 and above, below 54.4

11:00–14:00 spray 10 minutes, pause 10 minutes; voice announcement once an hour.

Red · Level 4

Heat index 54.4 and above

11:00–14:00 spray 10 minutes, pause 5 minutes; voice with warning sound every 30 minutes.

When relative humidity is above 70%, automatic sprinklers pause. At other hours they start manually and stop automatically after running 20 minutes. For the complete rules and announcement content, see "Heat Index Level Linkage: Automatic Sprinklers and Voice Announcements"。

Included Equipment

Detect: on-site microclimate data

Microclimate 5-in-1 Environmental Monitor - JNC

View product

Display: green, yellow and red lights

LED Traffic Light (Red/Yellow/Green)

View product

Decide: switch outputs by level

Environmental Monitoring Programmable Controller (PLCDO8)

View product

Want to deploy heat hazard linkage at your own site?

Tell us about your site and needs, and our sales contact will provide configuration advice and a quote.

Contact us